• 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
  • 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
  • 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
  • 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
  • 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
  • 33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse

33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse

Breaking Capacity: High
Type: Current Fuse
Usage: High Voltage
Shape: Circle
Fusing Speed: K, T, H
Fusing Device: Fuse Link
Samples:
US$ 30/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Liaoning, China
  • Overview
  • Product Description
  • Workshop and Testing
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
33kV100A 33kV200A 36kV100A 36kV200A 36kV300A
Standard
IEC 60282-2, IEEE C37.41
Transport Package
Standard Seafreight Package
Specification
Polymer Body
Trademark
ECI Power or OEM
Origin
China
HS Code
8536100000
Production Capacity
500000PC/Year

Product Description

Product Description

33-36kV Polymer Drop Out Fuse Cutout

Drop out fuses and load-drop fuses are outdoor high voltage protection appliances. They are installed on the high voltage side of the distribution transformer or on the branch line of the distribution line, used as a short circuit of the transformer and the line, overload protection and cut out load current.
Dropout fuse is composed of two parts: An insulating bracket and a fuse tube. The static contact is installed at two ends of the insulating bracket, the movable contact is installed at both ends of the fuse tube, and the fuse tube is composed of an inner arc extinguishing tube and an outer layer.
It consists of a phenolic paper tube or an epoxy glass tube. The load drop fuse enhances the elastic auxiliary contact and the arc extinguishing cover to divide and combine the load current.
Application environment:
1. Ambient temperature: -40 ~ +40ºC
2. Altitude above sea level: ≤3000m
3. Maximum wind speed: ≤35m/s
4. Earthquake intensity: ≤8 degrees
 

Rated 
Voltage
(KV)
Rated 
Current
(A)
Breaking 
current
(A)
BIL
(KV)
Power frequency
withstand voltage (KV)
Creepage 
distance
(mm)
Weight
(kgs)
Dimension
(cm)
 
 
 
33-36 100 8000 170 70 720 12.5 66*37.5*14  
33-36 200 10000 170 70 720 13.0  


 

Workshop and Testing

33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse

33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse

 

Packaging & Shipping
33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
Certifications

ISO 9001 2015   &  ISO 14001 2015   & ISO 45001 2018
 

33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse
33kv-36kv 100A 200A 300A Polymer Expulsion Drop out Fuse Cut out Fuse

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now